109 research outputs found

    Long-term cerebral thromboembolic complications of transapical endocardial resynchronization therapy

    Get PDF
    Purpose: Cardiac resynchronization therapy (CRT) is an established therapeutic option in selected heart failure patients (pts). However, the transvenous left ventricular (LV) lead implantation remains ineffectual in a considerable number of pts. Transapical LV (TALV) lead implantation is an alternative minimally invasive, surgical, endocardial implantation technique. The aim of the present prospective study is to determine the long-term outcome, including the cerebral thromboembolic complications, of pts

    Long-term cerebral thromboembolic complications of transapical endocardial resynchronization therapy

    Get PDF
    Purpose: Cardiac resynchronization therapy (CRT) is an established therapeutic option in selected heart failure patients (pts). However, the transvenous left ventricular (LV) lead implantation remains ineffectual in a considerable number of pts. Transapical LV (TALV) lead implantation is an alternative minimally invasive, surgical, endocardial implantation technique. The aim of the present prospective study is to determine the long-term outcome, including the cerebral thromboembolic complications, of pts

    Usefulness of electroanatomical mapping during transseptal endocardial left ventricular lead implantation

    Get PDF
    AimFailure rate to implant left ventricular (LV) lead transvenously is 4-8% in cardiac resynchronization therapy (CRT) patients. Epicardial lead placement is an alternative method and if not applicable case reports and small series showed the feasibility of endocardial LV lead implantation. Electroanatomical mapping might be a useful tool to guide this procedure.Methods and resultsFour patients had undergone endocardial LV lead implantation after unsuccessful transvenous implantation or epicardial LV lead dysfunction using the transseptal approach. Electroanatomical mapping was used to mark the location of the transseptal puncture. This location point guided the mapping catheter from the subclavian access and facilitated positioning of the LV lead at the adjacent latest activation area of the left ventricle detected by activation mapping. Endocardial active fixation LV leads were successfully implanted in all patients with stable electrical parameters immediately after implantation and over a mean follow-up of 18.3 months (lead impedance 520 +/- 177 vs. 439 +/- 119 Omega and pacing threshold 0.8 +/- 0.2 V, 0.5 ms vs. 0.6 +/- 0.1 V, 0.5 ms, respectively). Patients were maintained on anticoagulation therapy with a target international normalized ratio of 3.5-4.5 and did not show any thromboembolic, haemorrhagic events, or infection. Echocardiography showed significant improvement of LV systolic function with marked improvement of the functional status.ConclusionsElectroanatomical mapping is a useful technical tool to guide endocardial LV lead implantation. It helps to identify the location of the transseptal puncture and the use of activation mapping might facilitate location of the optimal lead positions during CRT

    The Global Risk Approach Should Be Better Applied in French Hypertensive Patients: A Comparison between Simulation and Observation Studies

    Get PDF
    The prediction of the public health impact of a preventive strategy provides valuable support for decision-making. International guidelines for hypertension management have introduced the level of absolute cardiovascular risk in the definition of the treatment target population. The public health impact of implementing such a recommendation has not been measured.We assessed the efficiency of three treatment scenarios according to historical and current versions of practice guidelines on a Realistic Virtual Population representative of the French population aged from 35 to 64 years: 1) BP≥160/95 mm Hg; 2) BP≥140/90 mm Hg and 3) BP≥140/90 mm Hg plus increased CVD risk. We compared the eligibility following the ESC guidelines with the recently observed proportion of treated amongst hypertensive individuals reported by the Etude Nationale Nutrition Santé survey. Lowering the threshold to define hypertension multiplied by 2.5 the number of eligible individuals. Applying the cardiovascular risk rule reduced this number significantly: less than 1/4 of hypertensive women under 55 years and less than 1/3 of hypertensive men below 45 years of age. This was the most efficient strategy. Compared to the simulated guidelines application, men of all ages were undertreated (between 32 and 60%), as were women over 55 years (70%). By contrast, younger women were over-treated (over 200%).The global CVD risk approach to decide for treatment is more efficient than the simple blood pressure level. However, lack of screening rather than guideline application seems to explain the low prescription rates among hypertensive individuals in France. Multidimensional analyses required to obtain these results are possible only through databases at the individual level: realistic virtual populations should become the gold standard for assessing the impact of public health policies at the national level

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data

    G Protein Subunit Dissociation and Translocation Regulate Cellular Response to Receptor Stimulation

    Get PDF
    We examined the role of G proteins in modulating the response of living cells to receptor activation. The response of an effector, phospholipase C-β to M3 muscarinic receptor activation was measured using sensors that detect the generation of inositol triphosphate or diacylglycerol. The recently discovered translocation of Gβγ from plasma membrane to endomembranes on receptor activation attenuated this response. A FRET based G protein sensor suggested that in contrast to translocating Gβγ, non-translocating Gβγ subunits do not dissociate from the αq subunit on receptor activation leading to prolonged retention of the heterotrimer state and an accentuated response. M3 receptors with tethered αq induced differential responses to receptor activation in cells with or without an endogenous translocation capable γ subunit. G protein heterotrimer dissociation and βγ translocation are thus unanticipated modulators of the intensity of a cell's response to an extracellular signal

    Angiostrongylosis-related restrictive pneumopathy assessed by arterial blood gas analysis in a dog

    Get PDF
    Pulmonary angiostrongylosis was diagnosed by the Baermann method and larval identification from faecal and bronchoalveolar lavage samples in a five-month- old male mongrel dog with dyspnoea and cough. Arterial blood gas analysis indicated arterial hypoxaemia and restrictive pneumopathy. In addition to the palliative treatment, fenbendazole was administered (50 mg/kg/24 h per os) for 14 days. The respiratory signs subsided within a short time clinically, but serial arterial blood gas analysis demonstrated an ongoing ventilation disorder. Repeated haematology, thoracic radiography, bronchoscopy and blood gas analysis were performed to follow the course of the disease. The most severe eosinophilia was detected after the beginning of the anthelmintic therapy, and the arterial pO2 level was permanently low. Arterial blood gas analysis provided the most adequate information about the course of the pneumopathy and it greatly facilitated the patient’s medical management

    Morphometrics as an Insight Into Processes Beyond Tooth Shape Variation in a Bank Vole Population

    Get PDF
    Phenotype variation is a key feature in evolution, being produced by development and the target of the screening by selection. We focus here on a variable morphological feature: the third upper molar (UM3) of the bank vole, aiming at identifying the sources of this variation. Size and shape of the UM3 occlusal surface was quantified in successive samples of a bank vole population. The first source of variation was the season of trapping, due to differences in the age structure of the population in turn affecting the wear of the teeth. The second direction of variation corresponded to the occurrence, or not, of an additional triangle on the tooth. This intra-specific variation was attributed to the space available at the posterior end of the UM3, allowing or not the addition of a further triangle.This size variation triggering the shape polymorphism is not controlled by the developmental cascade along the molar row. This suggests that other sources of size variation, possibly epigenetic, might be involved. They would trigger an important shape variation as side-effect by affecting the termination of the sequential addition of triangles on the tooth
    corecore